AISI 347 / UNS S34700 - Certified reference material for XRF, OES, combustion analysis, and laboratory elemental testing.
The Alloy Geek 347 Stainless Steel Certified Reference Material (CRM) is a certified analytical standard used for instrument calibration, verification, and method validation for niobium-stabilized austenitic stainless steels.
This CRM is suitable for benchtop XRF, handheld XRF, spark OES, combustion analyzers, and solution-based laboratory methods. It is commonly used in high-temperature stainless steel applications, petrochemical and power generation QA/QC programs, metals testing laboratories, and analyst training.
| Element | Certified Value (wt%) |
|---|---|
| Boron (B) | 0.0018 |
| Carbon (C) | 0.051 |
| Calcium (Ca) | 0.0011 |
| Cobalt (Co) | 0.072 |
| Chromium (Cr) | 17.27 |
| Copper (Cu) | 0.110 |
| Iron (Fe) | 69.1 |
| Manganese (Mn) | 1.67 |
| Molybdenum (Mo) | 0.27 |
| Nitrogen (N) | 0.039 |
| Niobium (Nb) | 0.58 |
| Nickel (Ni) | 10.08 |
| Oxygen (O) | 0.0053 |
| Phosphorus (P) | 0.022 |
| Sulfur (S) | 0.022 |
| Silicon (Si) | 0.677 |
| Tin (Sn) | 0.0034 |
| Vanadium (V) | 0.097 |
| Tungsten (W) | 0.013 |
| Zirconium (Zr) | 0.0028 |
Values enclosed in parentheses ( ) are provided for reference purposes only. These values are not certified and should not be used for calibration where certified values are required.
Common uses include:
This CRM provides stable reference values for chromium, nickel, manganese, titanium, and associated alloying elements. Carbon is not measured by XRF.
For spark-OES systems, the solid disc format is suitable for:
Chip samples produced from the same certified bulk material are suitable for:
What is a 347 stainless steel CRM used for?
It is used to calibrate and verify XRF, OES, and laboratory instruments that measure stainless steel chemistry.
Can this be used with handheld XRF?
Yes. It is suitable for handheld and benchtop XRF alloy verification and training.
Can this CRM be used for carbon analysis?
While carbon is not measured by XRF, it can be measured with an OES sample or with chip samples using combustion-based carbon analysis.
Is this suitable for ICP or wet chemistry?
Yes. Chips can be digested and used for ICP-OES, ICP-MS, and classical laboratory methods.
XRF Disc: 38 mm diameter × 3 mm thickness
Suitable for benchtop XRF and handheld XRF analysis.
OES Disc: 38 mm diameter × 19 mm thickness
Suitable for benchtop OES analysis.
Chip Sample: 100 g of stainless steel chips
Intended for combustion analysis (C, S, N), ICP-OES, ICP-MS, and classical wet chemistry following digestion.
All formats are produced from the same certified bulk material and represent the certified average composition.
Ships within 48 hours · Estimated delivery Jun 22 - Jun 27