Shopping security
The Evident Vanta Max handheld XRF analyzer is a premium portable X-ray fluorescence instrument designed for high-performance soil contamination screening and environmental field analysis. It represents the top tier of the Vanta series and is widely used when the highest analytical sensitivity and trace element resolution are required.
The Vanta Max combines a powerful X-ray source with advanced detector technology and Evident’s Axon signal processing platform. This configuration delivers higher X-ray count rates and improved measurement precision, enabling environmental professionals to detect trace contaminants at very low concentrations.
For environmental consultants, regulators, and remediation teams, the Vanta Max provides exceptional performance for identifying heavy metal contamination in soils including lead (Pb), arsenic (As), cadmium (Cd), mercury (Hg), and other regulated elements.
Want to compare other soil testing handheld XRF analyzers? Check out our complete collection of the Best Handheld XRF Analyzers for Soil Testing here.
Handheld XRF analyzers such as the Vanta Max are commonly used to screen soils for elements including:
These elements are frequently associated with industrial contamination, mining activity, historical manufacturing sites, and urban soil pollution.
The Vanta Max is commonly used to screen soils for RCRA hazardous metals, including:
Rapid field screening helps environmental professionals identify contaminated areas and prioritize samples for laboratory analysis.
| Specification | Details |
|---|---|
| X-ray Source | High-power X-ray tube (up to 50 kV depending on configuration) |
| Detector | High-performance silicon drift detector (SDD) |
| Analytical Range | Mg–U depending on mode |
| Signal Processing | Evident Axon technology for higher count rates |
| Weight | Approximately 3.7 lbs with battery |
| Display | High-brightness color touchscreen |
| Connectivity | Wi-Fi, Bluetooth, USB |
| Power | Rechargeable Li-ion battery |
| Environmental Rating | Rugged handheld design for field use |
Premium handheld XRF analyzers such as the Vanta Max provide excellent trace element sensitivity for environmental testing.
Typical geochemical detection limits for the Vanta platform include extremely low concentrations for many elements. For example, detection limits reported for geochemical analysis include:
These values are calculated using a three-sigma confidence level and 120-second analysis time per beam condition, demonstrating the strong trace element capability of the Vanta platform. Actual detection limits depend on sample matrix, measurement time, and the presence of interfering elements.
The Vanta Max offers the highest analytical performance in the Vanta series, providing superior limits of detection and improved trace element resolution for environmental contamination analysis.
Yes. The Vanta Max is widely used for environmental soil screening and can detect heavy metals such as lead, arsenic, cadmium, and related elements depending on soil composition and test conditions.
Yes. Handheld XRF analyzers such as the Vanta Max are commonly used to screen soils for RCRA hazardous metals including arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver.
Ships within 48 hours · Estimated delivery Jun 22 - Jun 27
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order