home > Victron Energy Lynx Shunt VE.Can (M10) busbar with main system fuse and battery monitoring 1000A 12V/24V/48V > Victron Energy Lynx Shunt VE.Can (M10) busbar with main system fuse and battery monitoring 1000A 12V/24V/48V
download picture
Victron Energy Lynx Shunt VE.Can (M10) busbar with main system fuse and battery monitoring 1000A 12V/24V/48VPhotonic Universe is an official distributor of products from Victron Energy the globally renowned manufacturer of high quality hybrid power charging solutions. Victron Energy products and accessories have a longstanding reputation for their outstanding reliability, innovative design and superior build quality. This Victron Energy Lynx Shunt, part of the Lynx distribution system, contains a positive busbar with a designated space for a main system
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

 

Photonic Universe is an official distributor of products from Victron Energy - the globally renowned manufacturer of high quality hybrid power charging solutions. Victron Energy products and accessories have a longstanding reputation for their outstanding reliability, innovative design and superior build quality.

This Victron Energy Lynx Shunt, part of the Lynx distribution system, contains a positive busbar with a designated space for a main system fuse, and negative busbar with a shunt for battery monitoring, rated at 1000A (nominal current rating).

The Lynx Shunt contains the system’s main fuse and is designed to hold a CNN fuse (up to 325A, not included) on the positive busbar. The fuse mounting studs are M8 with 63 mm spacing between centers. While the shunt is specifically designed for CNN fuses, other fuse types that fit these dimensions may also be compatible. 

For larger or more complex systems, an additional busbar piece is supplied. This optional piece allows you to replace the internal fuse with an external one, giving you the flexibility to mount the main fuse in a different location. The external busbar supports higher-rated fuses, including CNN fuses (35A to 800A), ANL fuses, or Mega fuses.

The Lynx Shunt continuously monitors the fuse, and if it blows, the power LED turns red and an alarm message is automatically sent to the connected GX device.

The Lynx Shunt operates in a similar fashion as other Victron Energy battery monitors (such as the Victron battery monitoring smartshunt). It contains a shunt and battery monitoring electronics. Readout of the battery monitor data is via a GX device or the VRM portal.

The Lynx Shunt can communicate via VE.Can with a GX device, such as the Cerbo GX (not included), which can be connected to the VRM (Victron Remote Monitoring) portal to enable remote monitoring. The GX device will show all measured parameters, operational state, battery SoC (state of charge) and alarms. Two RJ45 VE.Can terminators are supplied with the Lynx Shunt to be used when connecting to a GX device. An RJ45 cable (not included) is required to connect the Lynx Shunt to the GX device.  Once connected to the GX device, you can navigate to the Lynx Shunt settings menu on the GX device to view/set/change settings and parameters.

The Lynx Shunt has an alarm relay which can be programmed via the GX device to open or close using parameters such as battery State of charge, battery voltage, battery temperature and blown fuse. For example, the alarm relay can be used to start or stop a generator based on battery state of charge or battery voltage.

A temperature sensor (not included) is an optional item which can be connected to the Lynx Shunt to measure the battery temperature and drive the alarm relay. The temperature data or temperature alarms will also be sent to the GX device and from there to the VRM portal where the data is logged and can be accessed.

Depending on the desired outcome, the Lynx Shunt can be used by itself or in combination with a single or multiple other Lynx distribution system modules (not included) such as:

Click on the Details and Specifications tab for more information.

Victron Energy Lynx Shunt VE.Can (M10) busbar with main system fuse and battery monitoring 1000A 12V/24V/48V

Item no : 98702364488
sold recently : Login >>
US$ 180.00
Pay in 4 interest-free payments of $45.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 180.00

1-11

US$ 162.00

12-35

US$ 126.00

36-59

US$ 108.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches